CAN WE HELP?Enter your details and we’ll be in touch.
DC | Door Contact (Grade 2) |
---|---|
PIR | Passive Infra Red Movement Detector (Grade 2) |
DT | Dual Technology Movement Detector (Grade 2) |
BG | Break Glass Detector |
For a Grade 2 System, Anti-mask detectors are not a requirement.
DD243 still applies regarding overlapping coverage, so PIR coverage must not overlap.
It is acceptable for DT coverage to overlap with PIR or other DT’s.
A 45 second maximum entry timer is permitted, with a further fixed 30 second warning period, before Entry (unconfirmed) Alarm is notified to the ARC.
Grade 2 Systems would normally provide an ATS with at least 1 self powered audible WD (SAB/SCB), or 2 remotely powered WD’s.
Grade 2 Systems require 12 hours standby when using a ‘Type A’ PS.
ACE | Ancillary Control Equipment | (eg Exit Terminator Switch) |
---|---|---|
PACE | Portable Ancillary Control Equipment | (eg Remote Keyfob) |
CIE | Control and Indicating Equipment | (eg Alarm Panel) |
WD | Warning Device | (eg Bell Box, Sounders, Strobes) |
ATS | Alarm Transmission System | (Signalling System) |
ARC | Alarm Receiving Centre | (Monitoring Station) |
PS | Power Supply | (Power Supply for I & HAS) |